Construction of 290 sq ft livable addition with attached 69 sq ft storage under new awning, ICC2621-P, with ceiling joists, electric and plumbing for bathroom, washer and dryer on raised deck. 190 sq ft parking area and 80 sq ft covered deck. Type V-B construction. No deferred items. No special inspections. Minimum…
4700 block of E Main StContractor not listed$81,623 job value629 sq ft
Nov 5Mesa
CommercialIssued
Install Emergency Responder Radio Communications (ERRC/Erces) system.
1300 block of W University DrJDSowle Services DBA JM Integrators
Nov 5Mesa
Remodel and additions · Tenant ImprovementIssued
Tenant improvement in an existing construction type II-B concrete tilt-up warehouse. Modifications to exterior loading dock wall by replacing two overhead doors with one larger overhead door. Work includes demolition, new structural steel supports, infill walls, and replacement bollards. Special inspection for…
10700 block of E Elliot RdHaydon Companies LLC
Nov 5Mesa
Solar · ElectricalC of C Issued
Permit is only for the installation of one Tesla Powerwall 3 battery. All work to be performed per 2024 IRC, manufacture’s installation instructions and service utility provider specifications. Permit does not include photovoltaic system installation. Do not disconnect utility wires or meters. Schedule…
900 block of N 58th StScott Pickering
Nov 5Mesa
Pools · PlumbingC of C Issued
Installation of two 120 lb propane tanks surface mounted to wall. 35-ft of 2-in galvanized gasline buried 18-in with 18 gauge tracer wire from tanks to 400k BTU pool heater. Gasline to be installed per 2024 IFGC & fpd 6104.1.
6500 block of E Presidio StContractor not listed
Nov 5Mesa
Solar · ElectricalC of C Issued
Permit is only for installation of one Tesla Powerwall 3 battery and expansion pack. All work to be performed per 2024 IRC, manufacture’s installation instructions and service utility provider specifications. Permit does not include photovoltaic system installation. Do not disconnect utility wires or meters.…
6300 block of E Inglewood StScott Pickering
Nov 5Mesa
Remodel and additionsIssued
New 180 SF residential addition and 300 SF remodel. Remodel includes 180 SF livable area with walkable roof deck and 120 SF covered patio. Type V-B construction. Deferred truss calculations. No special inspections required. No utility upgrades. Minimum required building inspections: Footing, stem, strap/shear,…
6300 block of E Riverdale StContractor not listed$25,988 job value180 sq ft
Nov 5Mesa
New homesIssued
City of Mesa zoning clearance permit only for installation of 24-ft x 56-ft above ground set clayton MH serial no. Buc018120azab. No gas. Attached 10-ft x 40-ft awning, engineering provided by carl putnam #39702 expires 9/30/27. No other accessory structures at this time. Min two 9-ft x 18-ft paved 2-in asphalt or…
2000 block of N Center StRich Tukuafu
Nov 5Mesa
PoolsIssued
Construct a 320-SF swimming pool with natural gas heat. No spa. Installation of 50-ft of 1-1/2-in pe gas line buried 18-in deep with 18-gauge tracer wire from gas meter to 400k BTU pool heater. All gas lines are to be installed per 2024 IFGC & SW/com gas requirements. SW/com gas to determine if the meter needs to…
1000 block of S MapleContractor not listed$49,807 job value320 sq ft
Nov 5Mesa
Solar · ElectricalC of C Issued
Permit is only for the installation of one Tesla Powerwall 3 battery inside garage. B.e.s.s. Shall be installed in accordance with NFPA 70 per r327.4. All work to be performed per 2024 IRC, manufacture’s installation instructions and service utility provider specifications. Permit does not include photovoltaic…
3700 block of E Irwin AveContractor not listed
Nov 5Mesa
Solar · ElectricalC of C Issued
Permit is only for the installation of one Tesla Powerwall 3 battery. B.e.s.s. Shall be installed in accordance with NFPA 70 per r327.4. All work to be performed per 2024 IRC, manufacture’s installation instructions and service utility provider specifications. Permit does not include photovoltaic system…
10400 block of E Unity AveContractor not listed
Nov 5Mesa
New homesIssued
City of Mesa zoning clearance permit only for installation of 24' x 44' 2026 in-ground set champion MH serial #15700pha007099 a/b with a/c at rear. No gas or LP tanks. (1) 12' x 52' attached awning per icc 4244c. No other accessory structures at this time. Min (1) 9' x 18' covered paved unobstructed (2” asphalt or…
8800 block of E Baseline RdDvmhs Inc
Nov 5Mesa
Solar · ElectricalC of C Issued
Permit is only for the installation of one Tesla Powerwall 3 battery. All work to be performed per 2024 IRC, manufacture’s installation instructions and service utility provider specifications. Permit does not include photovoltaic system installation. Do not disconnect utility wires or meters. Schedule…
400 block of S WildroseScott Pickering
Nov 5Mesa
CommercialIssued
Electrical: Add panels/xfmrs P7 -> TR-P7A -> P7A from existing Distribution Board PD-2 as well installing new welding equipment Weld004, Weld002 and their smoke fume extractors and a few twist locks and some duplex/quad receptacles.
9000 block of E Technology AveDavid Watson
Nov 5Mesa
PlumbingC of C Issued
Plumbing permit to replace exisiting wet space with new shower in hall bathroom, including new valve and prefabricated arcylic walls. No structrual changes. New installations will tie into exisiting piping. No change to overall square footage. No other work under this permit. All work to comply with 2024 IRC and…
1200 block of N 72nd StContractor not listed
Nov 5Mesa
CommercialC of C Issued
Electrical - Resecure Electrical Panel Resecure electrical service panel to wall and reenergize. No new equipment. It is 1 panel on building 24 with multiple meters attached to it
100 block of S 56th StT & K Electric Company LLC
Nov 5Mesa
CommercialC of C Issued
Electrical - Resecure Electrical Panel Resecure electrical service panel to wall and reenergize. No new equipment.
100 block of S 56th StT & K Electric Company LLC
Nov 5Mesa
CommercialC of C Issued
Electrical - Resecure Electrical Panel Resecure electrical service panel to wall and reenergize. No new equipment.
100 block of S 56th StT & K Electric Company LLC
Nov 5Mesa
CommercialC of C Issued
Electrical - Resecure Electrical Panel Resecure electrical service panel to wall and reenergize. No new equipment.
100 block of S 56th StT & K Electric Company LLC
Nov 5Tempe
Remodel and additionsIssued
TI - suite 120 (range 107-120) gmp lab improvements: Vitalant
1500 block of W 14th StContractor not listed$450,000 job value
Nov 5Tempe
ElectricalIssued
Add to existing access control system (four doors): Stericycle
200 block of W Lodge DrContractor not listed$12,325 job value
Nov 5Tempe
Remodel and additionsIssued
Remove and repair deteriorated stem wall: Namude residence
1900 block of E Morgan DrContractor not listed$3,000 job value
Nov 5Tempe
ElectricalIssued
Access control installation - suite 137: National kidney foundation
300 block of W Warner RdContractor not listed$3,500 job value
Nov 5Tempe
Remodel and additionsIssued
Stem wall repair: Euge/hill residence
4400 block of S Mcallister AveContractor not listed$619 job value
Nov 5Tempe
ElectricalIssued
Replacement of 200 amp SES: R c & m e nelson jr revocable trust residence
1700 block of E Myrna LnContractor not listed$7,102 job value
Nov 5Tempe
Site work · Water/SewerReady to Issue
New 5/8 inch domestic water meter: Guadalupe Community Development Corporation
5600 block of E Calle PitayaContractor not listed
Nov 4Mesa
CommercialLarge projectIssued
New 179,250 SF shell warehouse construction type V-B unlimited area building. Scope is shell building with attached fire separated pump house. New (1) 2-inch domestic water meter, (1) 1.5-inch landscape meter, and (2) electric meters. Special Inspections Required: Emergency Responder Radio Coverage IFC 510,…
8100 block of E Sebring AveWillmeng Construction, Inc179,250 sq ft
Nov 4Mesa
Remodel and additions · Tenant ImprovementIssued
Install stand-alone electronic access control system on 10 existing commercial doors in an existing 114,000 SF, type III-B construction, group B and S-1 occupancy warehouse bldg with spec suite. Work includes installation of card readers, door position switches, request-to-exit devices, electric locking hardware,…
4000 block of S Signal Butte RdThe Alarm Butler LLC
Nov 4Mesa
Remodel and additions · Tenant ImprovementC of O Issued
Tenant improvement to create (2) suites in an existing 13,565 SF, type V-B building. Suite 101 is 4,342 SF, group B occupancy medical office and Suite 111 is 9,223 SF, group B occupancy medical office. Modifications include install of (2) walls at corridor to split space into (2) suites, install of sink with…
1800 block of S Extension RdConstruction & Project Management$952,464 job value4,342 sq ft
Nov 4Mesa
CommercialIssued
Modify existing fire alarm system by installed a new fire alarm control panel, fire alarm radio/communicator, surge protection and (3) 12V batteries.
Sources: City of Mesa open data, updated daily; City of Tempe open data, CC BY 4.0. Only the block is shown, never the owner’s name or house number. Last updated Nov 26.